CENTURION® SILVER SYSTEM
Управление на флуидите с авангардната гравитационна технология на CENTURION®.
В сравнение с други системи за факоемулсификация, СENTURION® SILVER се отличава със стабилна предна камера по време на факоемулсификация.
Персонализирани опции за отстраняване на катарактата:
- Наконечник Centurion OZil
- Наконечник Infiniti OZil
Авангардна флуидна система за точно и плавно управление на аспирацията и вакуума.
Имплантация на ВОЛ с помощта на лек, автоклавируем наконечник AutoSert®.
* Comparison with Stellaris† PC (Bausch + Lomb), WHITESTAR SIGNATURE† (AMO), EVA† (DORC). This comparison did not include ACTIVE SENTRY®.† Trademarks are property of their respective owners.
Референции:
- CENTURION® Silver System Operator’s Manual.
- Aravena C, Dyk DW, Thorne A, Fanney D, Miller KM. Aqueous volume loss associated with occlusion break surge in phacoemulsifiers from 4 different manufacturers. J Cataract Refract Surg. 2018 Jul;44(7):884-888.
- Sharif-Kashani P, Fanney D, Injev V. Comparison of occlusion break responses and vacuum rise times of phacoemulsification systems. BMC Ophthalmol. 2014;14:96.
- Thorne A, Dyk DW, Fanney D, Miller KM. Phacoemulsifier occlusion break surge volume reduction. J Cataract Refract Surg. 2018 Dec;44(12):1491-1496.
- Nicoli CM, Dimalanta R, Miller KM. Experimental anterior chamber maintenance in active versus passive phacoemulsification fluidics systems. J Cataract Refract Surg. 2016;42(1):157:162.
- Dyk DW, Miller KM. Mechanical model of human eye compliance for volumetric occlusion break surge measurements. J Cataract Refract Surg.2018 Feb;44(2):231-236.
- Alcon Data on File, REF-08357, 2020.
- Narendran N, et al. The Cataract National Dataset electronic multicentre audit of 55 567 operations: Risk stratification for posterior capsule rupture and vitreous loss. Eye. 2009;23:31–37.
- Salowi MA, et al. The Malaysian Cataract Surgery Registry: Risk indicators for posterior capsular rupture. Br J Ophthalmol. 2017;101:1466–1470.
- Khokhar S, Aron N, Sen S, Pillay G, Agarwal E. Effect of balanced phacoemulsification tip on the outcomes of torsional phacoemulsification using an active-fluidics system. J Cataract Refract Surg. 2017;43(1):22-28.
- Zacharias J. Thermal characterization of phacoemulsification probes operated in axial and torsional modes. J Cataract Refract Surg. 2015;41(1):208-216.
- Noguchi S, et al. Difference in torsional phacoemulsification oscillation between a balanced tip and a mini tip using an ultra-high-speed video camera. J Cataract Refract Surg. 2016;42:1511–1517.